This is an old revision of the document!
# Identify disks with failures /opt/MegaRAID/storcli/storcli64 /c0/eALL/sALL show all | grep -e 'State :' -e "Predictive Failure Count" Drive /c0/e8/s24 State : Predictive Failure Count = 1 /opt/MegaRAID/storcli/storcli64 /c0 /eall /sall show # Set locate beacon for ease of replacement /opt/MegaRAID/storcli/storcli64 /c0/e8/s24 start locate # Set disk offline and spundown /opt/MegaRAID/storcli/storcli64 /c0/e8/s24 set offline /opt/MegaRAID/storcli/storcli64 /c0/e8/s24 set missing /opt/MegaRAID/storcli/storcli64 /c0/e8/s24 spindown # Show rebuild status /opt/MegaRAID/storcli/storcli64 /c0/e8/s24 show rebuild # If no auto rebuild, force manually (/opt/MegaRAID/storcli/storcli64 /c0/e8/s24 rebuild)
/opt/MegaRAID/MegaCli/MegaCli64 -fwtermlog -dsply -a0 | more